UL 2079 Tested Seismic Fire Barrier Systems: styleJOINT I-FIRE®

Looking ahead to our 25th anniversary: International leaders in certified expansion joint fire containment systems. UL 2079 testing compliance and a 5-year warranty.

styleJOINT I-FIRE® provides certified 2-hour to 4-hour fire barrier blanket systems engineered to seal expansion joint openings in floors, walls, and ceilings against heat, toxic gases, and flames.

Tested under UL 2079 and ASTM E1966 with pre-burn cyclic seismic movement verification, I-FIRE guarantees life-safety integrity across major hospitals, data centers, airports, and commercial high-rises.

Stylewall Support

Frequently Asked Questions: styleJOINT FIRE

What fire-resistance ratings do styleJOINT FIRE barriers achieve?
styleJOINT FIRE assemblies are independently tested and certified under UL 2079 and ASTM E119 for 2, 3, and 4-hour fire endurance ratings across floor-to-floor, floor-to-wall, and wall-to-wall expansion joints.
What structural movement cycles are the fire blankets certified for?
Our fire barrier systems withstand dynamic multi-directional seismic drift, thermal cycling, and lateral shear (tested up to 5,000 continuous cycles under ASTM E1399) without tearing or compromising thermal insulation integrity.
Where are fire barrier expansion joints code-mandated?
They are required by IBC, NFPA 101, and international building codes in designated fire separations, high-rise commercial towers, hospital emergency wings, airport concourses, and egress corridors.
What building codes and testing standards do FIRE systems meet?
They comply with UL 2079 (Class I, II, III), ASTM E1966, ASTM E119, ASTM E1399, IBC 2024, NFPA 221, and CAN/ULC-S101 standards.

Technical Documentation

Product documentation · Check reference and version

Engineering & Specification Guide

styleJOINT FIRE Technical Support

styleJOINT I-FIRE: certified fire barrier blanket systems tested to UL 2079 / ASTM E1966 for 2-hour and 4-hour fire endurance in expansion joints.

Design Advantages & Performance of styleJOINT FIRE

Select styleJOINT FIRE according to the intended use, geometry and installation conditions of the project. Define the complete configuration, junctions and finishes to assess its suitability for the space. Consult the documentation for the selected reference when specifying performance.

Contact the Stylewall team to discuss the configuration and documentation available for each reference. Share drawings, dimensions and use requirements to prepare a technical proposal for the project.

Documentation and project requirements

Assess acoustic, movement, fire and safety requirements according to the product and its application. Check that each technical sheet or report corresponds to the configuration, materials and installation conditions being specified.

To assess environmental criteria, request the material, finish and maintenance information applicable to the selected reference. Relate the scope of each manufacturer declaration to the product and the specific project requirements.

Space Division Engineering & Seismic Protection